Fueling Products

Piping & Containment

Other Solutions

Image Not Available

UPP EN14125 Standard Pipe

EN14125 Standard UPP Primary Pipe can be used in both suction and pressure applications and is ideal for use as product fill lines or vapour vent lines in forecourts, marinas and airports where EN14125-approved pipe is the desired specification. Available in diameters ranging from 50 mm to 110 mm, UPP Primary Pipe comes in both coils as well as straight lengths to accommodate any installation. For pressure systems or environmentally sensitive installations, UPP Primary Pipe combines with the UPP Secondary Pipe to form an enhanced level of protection as UPP Coaxial (Secondary) Piping. The HDPE (high-density polyethylene) outer layer construction of all UPP Pipe allows all connections to be joined using the electrofusion welding process; providing a solid, single continuous system of pipework.

Click here to view the rest of the UPP product offering.

Advantages

  • Due to its impressive T1 rating, the EN-Standard UPP Pipe maintains a very high level of safety with operational temperature range of -40 °C to 50 °C, almost zero permeation and a burst pressure capability in excess of 40 bar.
  • Uses a highly efficient electrofusion welding system which connects the pipe and fittings to create a seamless direct burial pipework system.
  • This eliminates any leak paths from underground tank to the dispenser connection, ensuring full protection from the ingress of ground water and eliminates the chance of a spill into the environment.
  • Compatible with a wide range of fuels, alcohol mixtures and additives ensuring suitability for all fuel groups encountered around the world. Tested and approved for use with hydrocarbons, alcohol fuel blends and biofuels at pressures up to 10 bar.
  • No requirement for a concrete trench because HDPE is structurally resistant to weight of backfill material and dynamic traffic loads. 30 years of experience shows no material failures and no loss into the ground.
  • Extensive studies simulating fuel flow situations have demonstrated that, with a wide margin of safety, non-conductive pipe cannot be a source of spark ignition and is therefore a safe choice concerning the risks of electrostatic discharge.

Specifications

UPP EN14125 Standard Primary Pipe

Material PE100 with EVOH resin barrier
Primary pressure rating (bar/psi) 10/145
Primary colour Black with two clusters of four green stripes, clear inner liner
Temperature rating Class T1 rating (EN14125) -40 °C to 50 °C
Primary vacuum rating (-bar/″Hg) -0.9/-26.6

UPP EN14125 Standard Fill/Vent Pipe

Material PE100 with EVOH resin barrier
Primary pressure rating (bar/psi) 6/87
Primary colour Black with two clusters of four green stripes, clear inner liner
Temperature rating Class T1 rating (EN14125) -40 °C to 50 °C
Primary vacuum rating (-bar/″Hg) -0.9/-26.6

UPP EN14125 Coaxial (Secondary) Pipe

Material PE100 with EVOH resin barrier (Primary) and PE80 (Secondary)
Primary pressure rating (bar/psi) 10/145
Primary colour Black with two clusters of four green stripes, clear inner liner
Secondary colour Black with six green stripes
Secondary pressure rating (bar/psi) 5/72
Temperature rating Class T1 rating (EN14125) -40 °C to 50 °C
Primary vacuum rating (-bar/″Hg) -0.9/-26.6
Secondary vacuum rating (-basr/″Hg) -0.6/-17.8

UPP EN14125 Secondary Sleeve

Material PE80 (125mm and 160mm are PE100)
Secondary pressure rating (bar/psi) 5/72
Primary colour Black with six green stripes
Temperature rating Class T1 rating (EN14125) -40 °C to 50 °C
Primary vacuum rating (-bar/″Hg) -0.6/-17.8

Approvals

  • EN14125

Installation

Pipework is easily installed through the innovative electrofusion process which welds the system together using fittings and entry seals to provide one solid-construction system from the underground tank sump to the dispenser sump.

Ordering Info

UPP EN14125 Standard Primary Pipe

Model Description
(mm)
Ø (mm) Unit Pack Weight
(kg/m)
Weight
(lbs./ft.)
SDR Primary ID
(mm)
Bend Radius
(m)
001-050-006-E 50 50 6 m Stick 696m 0.66 0.45 11 40.9 0.75m
001-050-050-E 50 50 50 m Coil 50m 0.66 0.45 11 40.9 0.75m
001-050-100-E 50 50 100 m Coil 100m 0.66 0.40 11 40.9 0.75m
001-063-006-E 63 63 6 m Stick 408m 0.89 0.60 13.6 53.6 0.90m
001-063-007-E 63 63 7.5 m Stick 510m 0.89 0.60 13.6 53.6 0.90m
001-063-008-E 63 63 8 m Stick 544m 0.89 0.60 13.6 53.6 0.90m
001-063-100-E 63 63 100 m Coil 100m 0.89 0.60 13.6 53.6 0.90m
001-090-006-E 90 90 6 m Stick 204m 1.81 1.22 13.6 76.6 2.25m
001-090-050-E 90 90 50 m Coil 50m 1.81 1.22 13.6 76.6 2.25m
001-110-006-E 110 110 6 m Stick 138m 2.68 1.80 13.6 93.8 2.75m

UPP EN14125 Standard Fill/Vent Pipe

Model Description
(mm)
Unit Pack Weight
(kg/m)
Weight
(lbs./ft.)
SDR Primary ID
(mm)
Bend Radius
(m)
001-110-006-FILL-E 110 6 m Stick 138 2.22 1.49 17 96.8 2.75

UPP EN14125 Standard Coaxial (Secondary) Pipe

Model Description
(mm)
Unit Pack Weight
(kg/m)
Weight
(lbs./ft.)
SDR Primary ID
(mm)
Bend Radius
(m)
001-063-050-030-E 50 30 m Coil 30 1.17 0.78 11/26 40.9 0.90
001-063-050-100-E 50 100 m Coil 100 1.17 0.78 11/26 40.9 0.90
001-075-063-010-E 63 10 m Stick 460 1.56 1.05 13.6/26 53.6 1.12
001-075-063-030-E 63 30 m Coil 30 1.56 1.05 13.6/26 53.6 1.12
001-075-063-050-E 63 50 m Coil 50 1.56 1.05 13.6/26 53.6 1.12

UPP EN14125 Standard Secondary Sleeve

Model Description
(mm)
Unit Pack Weight
(kg/m)
Weight
(lbs./ft.)
SDR Bend Radius
(m)
000-063-006-SC-E 63 6 m Stick 544 0.5 0.34 26 0.9
000-075-006-SC-E 75 6 m Stick 276 0.67 0.45 26 1.12
000-075-008-SC-E 75 8 m Stick 368 0.67 0.45 26 1.12
000-110-006-SC-E 110 6 m Stick 138 1.46 0.98 26 2.75
000-125-006-SC-E 125 6 m Stick 90 1.89 1.27 26 3.1
000-160-006-SC-E 160 6 m Stick 54 3.02 2.10 26 N/A

UPP EN14125 Standard Primary/Secondary Pipe Diameter Compatibility Chart

    Primary
    50 mm (1.5") 63 mm (2") 90 mm (3") 110 mm (4")
Secondary 63 mm (2") X - - -
75 mm (3") - X - -
110 mm (4") Y Y X -
125 mm (5") Y Y Y X
160 mm (6") Y Y X X

EVOH Liner

The EVOH (ethylene vinyl-alcohol) resin layer now coating the interior of UPP EN14125 Primary Pipe provides an enhanced permeation barrier and an added level of protection with several other ancillary upgrades. The un-pigmented EVOH resin used in UPP Primary Pipe allows it to achieve an impressive T1 temperature rating under the EN14125 Standard, a testament to the strength and performance of the new liner. Additionally, the strength properties that un-pigmented EVOH resin and PE100 combination has allows for a reduction in the thickness of the HDPE outer layer while still maintaining the stringent permeation requirements and pressure rating of the EN14125 Standard, thus allowing for a greater inner diameter and the potential for an increase in flow rates as well as a decrease in pressure loss.